Aerial Insulated Cable — Rated voltage 1kV,10kV,35kV
Description
Aerial Insulated Cable — Rated Voltages: 1kV, 10kV, 35kV Application: The product is suitable for transmitting and distributing lines with rated voltages of 1kV, 10kV, and 35kV in tall buildings, rapidly developing areas, and wooded areas. Additionally, our range includes Instrumentation & Control Cable designed for precision instrumentation and control systems, as well as Low Voltage Power Cable for general power distribution applications.
Product parameters
-
Payment Type: L/C,T/T
-
Incoterm: FOB,Express Delivery,CFR,CIF,DAF,EXW,DES,FAS,FCA,CPT,CIP,DEQ,DDP,DDU
-
Min. Order: 150 Meter
Product Attributes
Packaging & Delivery
Product Description
Place Of Origin: China
Selling Units: Meter
Package Type: Export specific packaging
Package Type: Export specific packaging
Aerial Insulated Cable —— Rated voltage 1kV,10kV,35kV
Documentation: Aerial Insulated Cable, Instrumentation & control cable, and low voltage power cable
Aerial Insulated Cable — Rated Voltages: 1kV, 10kV, 35kV
Application: The product is suitable for transmitting and distributing lines with rated voltages of 1kV, 10kV, and 35kV in tall buildings, rapidly developing areas, and wooded areas. Additionally, our range includes Instrumentation & Control Cable designed for precision instrumentation and control systems, as well as Low Voltage Power Cable for general power distribution applications.
Operating characteristics:
- Continuous Permissible Operating Temperature:
PVC Insulation: 70℃
PE Insulation: 70℃
HDPE Insulation: 75℃
XLPE Insulation: 90℃
(Note: Similar temperature ratings apply to Instrumentation & Control Cable and Low Voltage Power Cable based on insulation material.) - Maximum Temperature of Cable under Short-Circuit (5s Maximum Duration):
PVC Insulation: 160℃
PE Insulation: 130℃
HDPE Insulation: 150℃
XLPE Insulation: 250℃
(Ensuring safety across all cable types, including those used in Instrumentation & Control and Low Voltage Power applications.) - Laying Temperature of Cable: Not less than -20℃.
Operating Ambient Temperature of Cables: -40℃ to 40℃.
(Suitable for a wide range of environmental conditions, enhancing versatility in various applications.) - Permissible Bending Radius of Cable:
For 0.6/1kV Cables:
Bending radius not less than 4D for cable diameter D<25mm.
Bending radius not less than 6D for cable diameter D≥25mm.
For 10kV & 35kV Cables:
Bending radius not less than 20(D+d) for single-core cables (Note: This may vary depending on specific cable design and manufacturer guidelines.)
(Note correction: The previously mentioned 15(D+d) for 10kV & 35kV single-core cables was a typographical error. The correct value is 20(D+d), as indicated here.)
Note: D represents the overall diameter of the cable, and d represents the overall diameter of the conductor.
Please note that specific characteristics and ratings may vary depending on the exact cable type, insulation material, and manufacturer specifications. Always refer to the product datasheet for detailed information.