N2XS(FL)2Y 20(24)kV Cable
Description
Engineered for reliable medium voltage distribution networks and generation units, the N2XS(FL)2Y 20(24)kV cable complies with IEC 60502-2 and IEC 60228 standards. Its UV-resistant sheath (ISO 4892-3) ensures durability in outdoor environments, suitable for direct burial and buried cable ducts. Rated for 12/20(24)kV (Uo/U), it withstands AC 42kV test voltage for 5 minutes. Operating temperatures range from -20°C to +60°C, with conductor temperatures up to +90°C during service and 250°C for short circuits (≤5 seconds). A minimum bending radius of 15x the cable diameter ensures flexibility in challenging installations. Built for resilience and safety, this cable delivers optimal performance in demanding infrastructure applications.
Product parameters
-
Payment Type: T/T,L/C
-
Incoterm: FOB,DDP,CFR,DDU,CIF,Express Delivery,EXW,FAS,DAF,FCA,DES,CPT,CIP,DEQ
-
Min. Order: 150 Meter
Package Type: Export specific packaging
N2XS(FL)2Y 20(24)kV Cable
Engineered for reliable medium voltage distribution networks and generation units, the N2XS(FL)2Y 20(24)kV cable complies with IEC 60502-2 and IEC 60228 standards. Its UV-resistant sheath (ISO 4892-3) ensures durability in outdoor environments, suitable for direct burial and buried cable ducts. Rated for 12/20(24)kV (Uo/U), it withstands AC 42kV test voltage for 5 minutes. Operating temperatures range from -20°C to +60°C, with conductor temperatures up to +90°C during service and 250°C for short circuits (≤5 seconds). A minimum bending radius of 15x the cable diameter ensures flexibility in challenging installations. Built for resilience and safety, this cable delivers optimal performance in demanding infrastructure applications.
We invest in testing solutions so you receive only the best MV&LV Power Cable/Energy Storage Cable/Solar Cable.Our world-class testing facility assures the quality and compliance of this superior insulation MV&LV power cable through a continuous and rigorous testing regime.
APPLICATION:
Medium voltage power cables for distribution networks and generation units, suitable for external installation including direct in ground and in buried cable ducts.UV Resistant.
CHARACTERISTICS:
Voltage Rating Uo儿 (Um):12/20 (24)kV
Test Voltage:42kV AC 50Hz (5 mins)
Temperature Rating:-20°℃ to +60°C Permissible Conductor Operating Temperature: +90°C Permissible Short Circuit Temperature up to 5 sec: 250°C
Minimum Bending Radius:15 x overall diameter
CONSTRUCTION:
Conductor:Class 2 Stranded Copper
Conductor Screen:Semi-conductive material
Insulation:XLPE (Cross-Linked Polyethylene)
Insulation Screen:Semi-conductive material (bonded)
Longitudinal Waterblocking:Semi-conductive swellable tape
Screen:Copper wires and copper tape
Longitudinal Waterblocking:Semi-conductive swellable tape
Radial Waterblocking:Al/PET (Aluminium /Polyester) Tape bonded to sheath
Outer Sheath:MDPE (Medium Density Polyethylene)
Sheath Colour:Red● Black
DIMENSIONS:
ELECTRICAL CHARACTERISTICS: