Contact us

NA2XS2Y 10(12)kV Cable

Description

Designed for medium voltage networks, the NA2XS2Y 10(12)kV cable meets IEC 60502-2 and IEC 60228 standards, with UV resistance (ISO 4892-3) for outdoor durability. Rated for 6/10(12)kV (Uo/U), it withstands AC 21kV test voltage for 5 minutes. Temperature ranges from -20°C to +60°C, with conductor operation up to +90°C and short-circuit resistance up to 250°C (≤5 sec). A 15x overall diameter bending radius ensures flexibility. Ideal for underground or outdoor installations, it combines mechanical robustness, environmental resistance, and reliable performance in harsh conditions. Built for safety and longevity, it suits demanding infrastructure projects.

Product parameters

  • Payment Type: L/C,T/T

  • Incoterm: FOB,CFR,DDU,DDP,CIF,Express Delivery,EXW,FAS,DAF,DES,FCA,CPT,CIP,DEQ

  • Min. Order: 150 Meter

Product Attributes Packaging & Delivery Product Description
Brand: Santai

Place Of Origin: China

Conductor Material: Aluminum

Insulation Materials: Xlpe
Selling Units: Meter
Package Type: Export specific packaging

NA2XS2Y 10(12)kV Cable


Designed for medium voltage networks, the NA2XS2Y 10(12)kV cable meets IEC 60502-2 and IEC 60228 standards, with UV resistance (ISO 4892-3) for outdoor durability. Rated for 6/10(12)kV (Uo/U), it withstands AC 21kV test voltage for 5 minutes. Temperature ranges from -20°C to +60°C, with conductor operation up to +90°C and short-circuit resistance up to 250°C (≤5 sec). A 15x overall diameter bending radius ensures flexibility. Ideal for underground or outdoor installations, it combines mechanical robustness, environmental resistance, and reliable performance in harsh conditions. Built for safety and longevity, it suits demanding infrastructure projects.

We invest in testing solutions so you receive only the best MV&LV Power Cable/Battery Connection Special Cable/Solar Cable.Our world-class testing facility assures the quality and compliance of this superior insulation MV&LV power cable through a continuous and rigorous testing regime.

APPLICATION:
Medium voltage power cables for distribution networks and generation units, suitable for external installation including in direct in ground and in buried cable ducts. UV Resistant.

CHARACTERISTICS:
Voltage Rating :Uo/U (Um)6/10(12)kV
Test Voltage:21kV AC 50Hz (5 mins)
Temperature Rating:-20°C to +60°C Permissible Conductor Operating Temperature: +90°C Permissible Short Circuit Temperature up to 5 sec: 250°C
Minimum Bending Radius:15 x overall diameter

CONSTRUCTION:
Conductor:Class 2 Stranded Aluminium
Conductor Screen:Semi-conductive material
Insulation:XLPE(Cross-Linked Polyethylene)
Insulation Screen:Semi-conductive material (bonded)
Screen:Copper wires and copper tape
Outer Sheath:MDPE (Medium Density Polyethylene)
Sheath Colour:Red ● Black
DIMENSIONS: ELECTRICAL CHARACTERISTICS: