Description

Engineered for high-voltage power transmission, the NA2XS2Y 30(36)kV cable features cross-linked polyethylene (XLPE) insulation and a UV-resistant PVC outer sheath (ISO 4892-3), meeting IEC 60502-2 and IEC 60228 standards. Rated for 18/30(36)kV systems, it withstands 63kV AC test voltage (50Hz, 5 mins) and operates reliably from -20°C to +60°C.

Product parameters

  • Payment Type: L/C,T/T

  • Incoterm: FOB,DDP,CFR,DDU,CIF,Express Delivery,EXW,FAS,DAF,FCA,DES,CPT,CIP,DEQ

  • Min. Order: 150 Meter

Product Attributes Packaging & Delivery Product Description
Brand: Santai
Selling Units: Meter
Package Type: Export specific packaging

NA2XS2Y 30(36)kV Cable


Engineered for high-voltage power transmission, the NA2XS2Y 30(36)kV cable features cross-linked polyethylene (XLPE) insulation and a UV-resistant PVC outer sheath (ISO 4892-3), meeting IEC 60502-2 and IEC 60228 standards. Rated for 18/30(36)kV systems, it withstands 63kV AC test voltage (50Hz, 5 mins) and operates reliably from -20°C to +60°C.
The copper conductor handles up to +90°C continuously, surviving short circuits up to 250°C for 5 seconds. With a 15x overall diameter bending radius, it suits confined installations. UV resistance ensures longevity in outdoor exposure, while thermal stability supports high-demand applications.
Ideal for utility grids, industrial plants, or renewable energy infrastructure, this cable delivers durability and performance in harsh environments. Its robust design balances flexibility, safety, and compliance for modern power networks.

We invest in testing solutions so you receive only the best MV&LV Power Cable/Battery Connection Special Cable/Wind Power Special Cable.Our world-class testing facility assures the quality and compliance of this superior insulation MV&LV power cable through a continuous and rigorous testing regime.

APPLICATION:
Medium voltage power cables for distribution networks and generation units, suitable for external installation including in direct in ground and in buried cable ducts. UV Resistant.

CHARACTERISTICS:
Voltage Rating :Uo/U (Um)18/30(36)kV
Test Voltage:63kV AC 50Hz (5 mins)
Temperature Rating:-20°C to +60°C Permissible Conductor Operating Temperature: +90°C Permissible Short Circuit Temperature up to 5 sec: 250°C
Minimum Bending Radius:15 x overall diameter

CONSTRUCTION:
Conductor:Class 2 Stranded Aluminium
Conductor Screen:Semi-conductive material
Insulation:XLPE (Cross-Linked Polyethylene)
Insulation Screen:Semi-conductive material (bonded)
Screen:Copper wires and copper tape
Outer Sheath:MDPE (Medium Density Polyethylene)
Sheath Colour:Red ● Black

DIMENSIONS:
ELECTRICAL CHARACTERISTICS: