MV&LV Power Cable (53 goods)

N2XBH Power Cable Solutions for Efficient Electrical Distribution

N2XBH Power Cable Solutions for Efficient Electrical Distribution

Our MV&LV Power Cable can meet standards of DIN VDE 0276-604,TS HD 604.S1.IS 1516.1.IEC 60502-1.Flame retardant according to lEC 60332-3-24 Cat.C .Low Smoke Zero Halogen according to IEC/EN 60754-1/2,IEC/EN 61034-1/2.

Advanced N2XFGbY Copper Conductor Power Cable

Advanced N2XFGbY Copper Conductor Power Cable

Our MV&LV Power Cable can meet standards of IEC 60502-1,VDE 0276-603 Flame retardant according to lEC 60332-1 We invest in testing solutions so you receive only the best MV&LV power cable/Solor Power Special Cable/Fire Resistant Cable.Our world-class testing facility assures the quality and compliance of this superior insulation MV&LV power cable through a continuous and rigorous testing regime. We are on a journey to Net Zero.We've committed to near-term emissions reductions and a net-zero target with the Science Based Targets initiative and we're a signatory to the United Nations Global Compact Sustainable Development Goals.

High-Performance N2XBY Cable

High-Performance N2XBY Cable

Our MV&LV Power Cable can meet standards of IEC 60502-1.VDE 0276-603,IS 1516.1.IEC/EN 60228.Flame retardant according to lEC/EN 60332-1 We invest in testing solutions so you receive only the best MV&LV power cable/Solor Power Special Cable/Fire Resistant Cable.Our world-class testing facility assures the quality and compliance of this superior insulation MV&LV Power Cable through a continuous and rigorous testing regime. We are on a journey to Net Zero.We've committed to near-term emissions reductions and a net-zero target with the Science Based Targets initiative and we're a signatory to the United Nations Global Compact Sustainable Development Goals.

Reliable N2XCY Cable for Low Voltage Applications

Reliable N2XCY Cable for Low Voltage Applications

Our MV&LV Power Cable can meet standards of IEC 60502-1,VDE 0276-603,1S 1516.1 Flame retardant according to lEC 60332-1 We invest in testing solutions so you receive only the best MV&LV power cable/Solor Power Special Cable/Fire Resistant Cable.Our world-class testing facility assures the quality and compliance of this superior insulation MV&LV Power Cable through a continuous and rigorous testing regime. We are on a journey to Net Zero.We've committed to near-term emissions reductions and a net-zero target with the Science Based Targets initiative and we're a signatory to the United Nations Global Compact Sustainable Development Goals.

N2XH XLPE FRNC 0.6kV Cable

N2XH XLPE FRNC 0.6kV Cable

The N2XH XLPE FRNC 0.6kV Cable is a halogen-free, flame-retardant Power Cable designed for low-voltage (LV) systems up to 1kV. Featuring copper conductors, cross-linked polyethylene (XLPE) insulation, and a FRNC polyolefin sheath, it operates reliably from -30°C to +90°C. Ideal for public buildings, data centers, and industrial facilities, it meets stringent fire safety standards (EN 50266-2-4) with minimal smoke emission.

N2XS2Y 6/10(12)kV Cables

N2XS2Y 6/10(12)kV Cables

Engineered for medium voltage distribution networks and generation units, these cables excel in outdoor installations, including direct burial and underground ducts. Their UV-resistant sheathing (ISO 4892-3) ensures durability under prolonged sun exposure.

N2XS2Y 12/20(24)kV Cables

N2XS2Y 12/20(24)kV Cables

Designed for robust energy distribution in medium voltage networks, these cables suit outdoor installations including direct burial and underground ducts. UV-resistant sheathing (ISO 4892-3) ensures long-term performance under solar exposure.

N2XS2Y 30(36)kV Cables

N2XS2Y 30(36)kV Cables

Designed for medium-voltage power distribution, the N2XS2Y cable complies with IEC 60502-2 and IEC 60228, ensuring global reliability. Its cross-linked polyethylene (XLPE) insulation and UV-resistant sheath (tested to ISO 4892-3) enable durable outdoor use. Rated for 18/30 (36)kV with a 63kV AC test voltage, it delivers safe energy transmission.

N2XS2Y XLPE MDPE 8.7/15(17.5)kV Cable

N2XS2Y XLPE MDPE 8.7/15(17.5)kV Cable

Engineered for medium-voltage wind energy projects, this cable features XLPE insulation and MDPE sheathing, meeting IEC 60502-2 and EN 60228 standards. UV-resistant design ensures longevity in harsh outdoor environments. Rated 8.7/15(17.5)kV, it operates safely up to 90°C conductor temperature, withstanding short-circuit temperatures up to 250°C (≤5 sec). The metallic screen maintains integrity at 80°C during faults.

N2XS2Y XLPE MDPE 15(17.5)kV Cable

N2XS2Y XLPE MDPE 15(17.5)kV Cable

Engineered for medium-voltage networks, this cable combines XLPE insulation and MDPE sheathing, adhering to IEC 60502-2 and EN 60228 (equivalent to IEC 60228). UV-resistant properties ensure outdoor durability. Rated 8.7/15(17.5)kV, it operates reliably at 90°C conductor temperature, withstanding short-circuit temperatures up to 250°C (≤5 sec). The metallic screen maintains integrity at 80°C during faults.

N2XS(F)2Y 6/10 (12)kV Cable

N2XS(F)2Y 6/10 (12)kV Cable

Engineered for medium-voltage networks, this cable features cross-linked polyethylene (XLPE) insulation and UV-resistant sheathing (ISO 4892-3), ensuring durability in outdoor environments. Compliant with IEC 60502-2 and IEC 60228, it delivers safe performance for direct burial or duct installations.

N2XS(F)2Y 20(24)kV Cable

N2XS(F)2Y 20(24)kV Cable

Designed for reliable energy distribution in medium voltage networks and generation units, the N2XS(F)2Y 20(24)kV cable meets global standards IEC 60502-2 and IEC 60228. Its UV-resistant sheath (ISO 4892-3) ensures durability in outdoor environments, including direct burial and buried duct installations. Rated for 12/20(24)kV (Uo/U(Um)), it withstands AC 42kV test voltage for 5 minutes. Operating temperatures range from -20°C to +60°C, with conductor temperatures up to +90°C during service and 250°C for short circuits (≤5 sec). Flexible installation is supported by a minimum bending radius of 15x the cable diameter. This robust solution combines safety, longevity, and adaptability for demanding infrastructure projects.