Cables (296 goods)
N2XS2Y 6/10(12)kV Cables
Engineered for medium voltage distribution networks and generation units, these cables excel in outdoor installations, including direct burial and underground ducts. Their UV-resistant sheathing (ISO 4892-3) ensures durability under prolonged sun exposure.
N2XS2Y 12/20(24)kV Cables
Designed for robust energy distribution in medium voltage networks, these cables suit outdoor installations including direct burial and underground ducts. UV-resistant sheathing (ISO 4892-3) ensures long-term performance under solar exposure.
N2XS2Y 30(36)kV Cables
Designed for medium-voltage power distribution, the N2XS2Y cable complies with IEC 60502-2 and IEC 60228, ensuring global reliability. Its cross-linked polyethylene (XLPE) insulation and UV-resistant sheath (tested to ISO 4892-3) enable durable outdoor use. Rated for 18/30 (36)kV with a 63kV AC test voltage, it delivers safe energy transmission.
N2XS2Y XLPE MDPE 8.7/15(17.5)kV Cable
Engineered for medium-voltage wind energy projects, this cable features XLPE insulation and MDPE sheathing, meeting IEC 60502-2 and EN 60228 standards. UV-resistant design ensures longevity in harsh outdoor environments. Rated 8.7/15(17.5)kV, it operates safely up to 90°C conductor temperature, withstanding short-circuit temperatures up to 250°C (≤5 sec). The metallic screen maintains integrity at 80°C during faults.
N2XS2Y XLPE MDPE 15(17.5)kV Cable
Engineered for medium-voltage networks, this cable combines XLPE insulation and MDPE sheathing, adhering to IEC 60502-2 and EN 60228 (equivalent to IEC 60228). UV-resistant properties ensure outdoor durability. Rated 8.7/15(17.5)kV, it operates reliably at 90°C conductor temperature, withstanding short-circuit temperatures up to 250°C (≤5 sec). The metallic screen maintains integrity at 80°C during faults.
N2XS(F)2Y 6/10 (12)kV Cable
Engineered for medium-voltage networks, this cable features cross-linked polyethylene (XLPE) insulation and UV-resistant sheathing (ISO 4892-3), ensuring durability in outdoor environments. Compliant with IEC 60502-2 and IEC 60228, it delivers safe performance for direct burial or duct installations.
N2XS(F)2Y 20(24)kV Cable
Designed for reliable energy distribution in medium voltage networks and generation units, the N2XS(F)2Y 20(24)kV cable meets global standards IEC 60502-2 and IEC 60228. Its UV-resistant sheath (ISO 4892-3) ensures durability in outdoor environments, including direct burial and buried duct installations. Rated for 12/20(24)kV (Uo/U(Um)), it withstands AC 42kV test voltage for 5 minutes. Operating temperatures range from -20°C to +60°C, with conductor temperatures up to +90°C during service and 250°C for short circuits (≤5 sec). Flexible installation is supported by a minimum bending radius of 15x the cable diameter. This robust solution combines safety, longevity, and adaptability for demanding infrastructure projects.
N2XS(F)2Y 30(36)kV Cable
Engineered for robust energy distribution in medium voltage systems, the N2XS(F)2Y 30(36)kV cable adheres to IEC 60502-2 and IEC 60228 standards, ensuring global compliance. Its UV-resistant sheath (ISO 4892-3) guarantees long-term outdoor performance, ideal for direct burial or installation in underground ducts. Rated for 18/30(36)kV (Uo/U(Um)), it withstands AC 63kV test voltage for 5 minutes. Operating temperatures span -20°C to +60°C, with conductor temperatures up to +90°C during normal use and 250°C for short circuits (≤5 seconds). A minimum bending radius of 15x the cable diameter ensures flexibility in challenging installations. Built for durability and safety, this cable delivers reliable performance in demanding infrastructure projects.
N2XS(FL)2Y 10(12)kV Cable
Designed for medium voltage networks requiring enhanced environmental protection, the N2XS(FL)2Y 10(12)kV cable meets IEC 60502-2 and IEC 60228 standards. Its UV-resistant (ISO 4892-3) and water-resistant (EN 60529) sheath ensures durability in outdoor and wet environments, suitable for direct burial, underground ducts, or exposed installations. Rated for 6/10(12)kV (Uo/U), it withstands AC 21kV test voltage for 5 minutes. Operating temperatures range from -20°C to +60°C, with conductor temperatures up to +90°C during service and 250°C for short circuits (≤5 sec). A minimum bending radius of 15x the cable diameter ensures flexibility. Ideal for resilient infrastructure in harsh conditions.
N2XS(FL)2Y 20(24)kV Cable
Engineered for reliable medium voltage distribution networks and generation units, the N2XS(FL)2Y 20(24)kV cable complies with IEC 60502-2 and IEC 60228 standards. Its UV-resistant sheath (ISO 4892-3) ensures durability in outdoor environments, suitable for direct burial and buried cable ducts. Rated for 12/20(24)kV (Uo/U), it withstands AC 42kV test voltage for 5 minutes. Operating temperatures range from -20°C to +60°C, with conductor temperatures up to +90°C during service and 250°C for short circuits (≤5 seconds). A minimum bending radius of 15x the cable diameter ensures flexibility in challenging installations. Built for resilience and safety, this cable delivers optimal performance in demanding infrastructure applications.
N2XS(FL)2Y 18/30(36)kV Cable
Designed for robust medium voltage distribution networks and generation units, the N2XS(FL)2Y 18/30(36)kV cable complies with IEC 60502-2 and IEC 60228 standards. Its UV-resistant sheath (ISO 4892-3) ensures durability in outdoor environments, suitable for direct burial or installation in buried cable ducts. Rated for 18/30(36)kV (Uo/U), it withstands AC 63kV test voltage for 5 minutes. Operating temperatures range from -20°C to +60°C, with conductor temperatures up to +90°C during normal use and 250°C for short circuits (≤5 seconds). A minimum bending radius of 15x the cable diameter ensures flexibility in challenging installations. Built for resilience and safety, this cable delivers reliable performance in demanding infrastructure applications.
N2XS(FL)2Y XLPE HDPE 8.7/15 (17.5)kV Cable
Engineered for wind energy installations and medium voltage distribution networks, this cable combines XLPE insulation and HDPE sheathing for enhanced durability. Compliant with IEC 60502-2 and EN 60228 standards, it features UV resistance (ISO 4892-3) and dual-sealed longitudinal/radial waterproofing to prevent moisture ingress. Rated for 8.7/15(17.5)kV (Uo/U), it withstands AC 35kV test voltage for 5 minutes. Operating temperatures range from -20°C to +60°C, with conductor temperatures up to +90°C during service and 250°C for short circuits (≤5 seconds). A minimum bending radius of 15x the cable diameter ensures flexible installation in challenging environments. Designed for resilience, it delivers reliable performance in renewable energy and outdoor infrastructure projects.